Input power loss detected

Want this fix in your inbox? Full E03 guide + every Manitowoc code, printable, free.

What does Manitowoc E03 mean?

E03 is an informational event, not a shutdown fault. The Manitowoc Indigo control detects a loss of incoming power by monitoring voltage on power-up. When power is restored after an interruption, the board compares its internal clock to stored data; if a gap is detected, it logs E03 in the event log. The machine resumes normal operation automatically after the power event.

Symptoms

  • E03 appears in the event log after a power outage or circuit interruption.
  • Machine restarts and resumes ice production without manual intervention.
  • Event log timestamp shows a gap corresponding to the outage duration.
  • No active alarm or shutdown — machine runs normally after logging.

Common causes

  • Utility power outage interrupting supply to the ice machine.
  • Tripped circuit breaker or blown fuse on the dedicated circuit.
  • Loose or corroded power connection at the machine or disconnect.
  • Voltage sag or brownout triggering a control board reset.

Diagnostic steps

  1. 01

    Check the circuit breaker and disconnect

    Inspect the dedicated circuit breaker for the ice machine. Reset if tripped and investigate the cause of the trip before restoring power.

  2. 02

    Inspect power connections at the machine

    With power off, check the line-side terminals inside the machine for tightness and corrosion. Loose connections cause intermittent power loss that logs repeated E03 events.

  3. 03

    Verify supply voltage

    Measure supply voltage at the machine terminals under load. Voltage outside the ±10% tolerance of the nameplate rating can cause control board resets.

  4. 04

    Review event log frequency

    Access the Indigo event log and note how often E03 appears. Isolated events tied to known outages are normal. Frequent unexplained entries indicate an electrical supply problem requiring investigation.

Keep this fix — get it by email with every Manitowoc error code

A clean printable version of this Manitowoc E03 guide + the full Manitowoc code pack (30 codes), straight to your inbox. Free.

I am a — required, one click

When to call a professional

If E03 appears repeatedly without a known power outage, or if the supply voltage is unstable, contact a licensed electrician to evaluate the branch circuit, panel connections, and supply quality. Do not attempt to modify branch circuit wiring without proper electrical credentials.

Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.

Open a ticket — free account