Sveba-Dahlen InF6
Unknown option installed in the converter — SD-180 (Schneider frequency converter)
Source: Sveba-Dahlen_SD180_TouchscreenManual_CK_EN.pdf
What does Sveba-Dahlen InF6 mean?
The SD-180's Schneider frequency converter has detected that an option card or module installed in the drive is not recognised by the converter's firmware. The drive cannot identify or communicate with the fitted option, preventing normal operation. This fault typically occurs after installation of a non-approved or incompatible option module.
Symptoms
- InF6 fault code displayed on the SD-180 touchscreen at power-up
- Converter fails to initialise and will not accept a run command
- Fault appears immediately after an option card or module has been installed or changed
- No drive output to the motor regardless of control input state
- Other converter parameters may be inaccessible until the fault is cleared
Common causes
- An unrecognised or incompatible option card installed in the Schneider converter option slot
- Option module firmware version not supported by the installed converter firmware
- Option card from a different Schneider drive family fitted in error
- Physically damaged option card connector causing misidentification
- Option card not fully seated in its slot, causing partial or no recognition
Diagnostic steps
- 01
Isolate and lock out the SD-180
Switch off at the main isolator and apply lockout/tagout. Wait a minimum of 5 minutes for the converter DC bus to discharge before opening the enclosure.
- 02
Identify the installed option
Locate the option card or module installed in the Schneider converter and record its part number and revision. Cross-reference this against the approved options list in the SD-180 service manual to confirm whether it is a supported module.
- 03
Remove or replace the unrecognised option
If the option is confirmed incompatible or unrecognised, remove it from the converter slot. If an option is required, fit only the approved replacement module specified in the Sveba-Dahlen SD-180 documentation.
- 04
Re-seat any retained option card
If the option card is approved but was not fully seated, remove it completely, inspect the connector for damage or contamination, and re-seat it firmly in the correct slot before restoring power.
- 05
Power up and verify fault clearance
Restore power to the SD-180 and check the touchscreen for clearance of InF6. If the fault clears, verify full converter operation through a complete test cycle before returning the oven to service.
Keep this fix — get it by email with every Sveba-Dahlen error code
A clean printable version of this Sveba-Dahlen InF6 guide + the full Sveba-Dahlen code pack (59 codes), straight to your inbox. Free.
When to call a professional
Escalate to an authorised Sveba-Dahlen or Schneider drive technician if you cannot identify the installed option, if no approved replacement is available, or if InF6 persists after fitting a confirmed compatible module. Selecting or configuring option cards incorrectly in the frequency converter can compromise oven safety and motor control.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Sveba-Dahlen error codes
Trailing error — pulse sensor speed response does not match the reference (SD-180 Schneider frequency converter)
ASFAngle error — motor phase disconnected or motor inductance too high during phase-shift angle measurement (SD-180 Schneider frequency converter)
bLFBrake control fault — opening current not achieved or brake closure frequency issue (SD-180 Schneider frequency converter)
brFBrake feedback fault — sensor contact mismatch or motor not stopping quickly enough under brake (SD-180 Schneider frequency converter)
CFFIncorrect configuration — additional card replaced/removed, mismatched control card, or illogical configuration (SD-180 Schneider frequency converter)
CFIInvalid configuration — current converter configuration via bus or communication network is illogical (SD-180 Schneider frequency converter)
CFI2Invalid configuration (variant 2) — current converter configuration via bus or communication network is illogical (SD-180 Schneider frequency converter)
CnFCommunication network fault — error in the communication card (SD-180 Schneider frequency converter)
COFCANopen communication bus interruption on SD-180 (Schneider frequency converter)
CrF1Capacitor charging relay control error or faulty charging resistor on SD-180 (Schneider frequency converter)
CSFInvalid channel switch fault on SD-180 (Schneider frequency converter)
dLFAbnormal dynamic load variation detected on SD-180 (Schneider frequency converter)