Sveba-Dahlen InFA Error Code
Internal power circuits fault — input section not functioning properly in SD-180 (Schneider frequency converter)
Source: Sveba-Dahlen_SD180_TouchscreenManual_CK_EN.pdf
What does Sveba-Dahlen InFA mean?
The SD-180's Schneider frequency converter has detected that its internal input power section is not functioning correctly. The input section includes the rectifier stage and associated components that convert incoming mains AC to the DC bus voltage that powers the drive. This fault indicates a significant hardware issue within the converter's power electronics.
Symptoms
- InFA fault code displayed on the SD-180 touchscreen
- Converter fails to build up normal DC bus voltage on power-up
- No drive output to the motor; oven conveyor or deck drive does not operate
- Possible tripping of upstream fuses or circuit breakers if input components have failed short
- Fault present from initial power-up with no run command required to trigger it
Common causes
- Failure of the rectifier bridge or input power components within the converter
- Damage to the converter input section caused by mains voltage spikes or surges
- Incorrect mains supply voltage being applied to the converter input terminals
- Phase loss on the incoming mains supply causing abnormal input section behaviour
- Internal precharge circuit fault preventing normal DC bus energisation
- Physical damage to the converter power board affecting the input stage
Ask the AskWhiz AI about Sveba-Dahlen InFA
AskWhiz
online
Diagnostic steps
Verify incoming mains supply
Before opening the converter, use a calibrated voltmeter to confirm that the mains supply to the SD-180 is correct in voltage, frequency, and that all phases are present and balanced. Correct any supply issues before proceeding.
Isolate, lock out, and discharge
Switch off at the main isolator, apply lockout/tagout, and wait at least 5 minutes for the DC bus capacitors inside the converter to fully discharge before opening the enclosure.
Inspect input terminals and wiring
Check the converter's mains input terminals for loose connections, signs of overheating, or arcing. Tighten any loose terminals to the torque values specified in the SD-180 service manual.
Inspect input power components visually
Examine the converter power PCB and rectifier components for visible damage such as burn marks, cracked components, or bulged capacitors. Do not attempt component-level repairs in the field.
Document and escalate
Record all findings including supply measurements, any visible damage, and the conditions under which InFA appeared. Provide this information to the attending drive technician to expedite diagnosis and repair.
When to call a professional
InFA indicates a fault in the converter's internal power electronics that requires specialist drive repair or converter replacement. Do not attempt to continue operating the SD-180 with this fault active. Escalate immediately to an authorised Sveba-Dahlen service engineer or Schneider drive specialist, as further operation risks permanent converter damage or electrical hazards.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Sveba-Dahlen documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Sveba-Dahlen Error Codes
Trailing error — pulse sensor speed response does not match the reference (SD-180 Schneider frequency converter)
Angle error — motor phase disconnected or motor inductance too high during phase-shift angle measurement (SD-180 Schneider frequency converter)
Brake control fault — opening current not achieved or brake closure frequency issue (SD-180 Schneider frequency converter)
Brake feedback fault — sensor contact mismatch or motor not stopping quickly enough under brake (SD-180 Schneider frequency converter)
Incorrect configuration — additional card replaced/removed, mismatched control card, or illogical configuration (SD-180 Schneider frequency converter)
Invalid configuration — current converter configuration via bus or communication network is illogical (SD-180 Schneider frequency converter)
Invalid configuration (variant 2) — current converter configuration via bus or communication network is illogical (SD-180 Schneider frequency converter)
Communication network fault — error in the communication card (SD-180 Schneider frequency converter)
CANopen communication bus interruption on SD-180 (Schneider frequency converter)
Capacitor charging relay control error or faulty charging resistor on SD-180 (Schneider frequency converter)
Invalid channel switch fault on SD-180 (Schneider frequency converter)
Abnormal dynamic load variation detected on SD-180 (Schneider frequency converter)