System low pressure protection

Source: ACiQ/ACiQ_ACIQ-SZ-ODU-EH-SH-SM-EN-01-051625-6K-60K-230V-NA-H-240527_ServiceManual_HVAC_EN.pdf

Want this fix in your inbox? Full PC31 guide + every ACiQ code, printable, free.

What does ACiQ PC31 mean?

PC31 is a system low pressure protection fault. The outdoor pressure switch cuts off the system because the low-side pressure has dropped below 0.13 MPa, and the LED displays the failure code. Low pressure usually indicates a refrigerant shortage or a fault at the low-pressure protector or its wiring.

Symptoms

  • PC31 shown on the display
  • System cuts off on low-pressure protection
  • Weak cooling or heating output
  • Possible signs of a refrigerant leak

Common causes

  • Low refrigerant charge or a refrigerant leak
  • Low pressure protector miswired or faulty
  • Broken low-pressure switch (open circuit)
  • Refrigerant-system blockage or fault

Diagnostic steps

  1. 01

    Check the protector wiring

    Confirm the low pressure protector and main control board are wired correctly; reconnect them if not.

  2. 02

    Test the low-pressure switch

    Disconnect the plug and measure the resistance of the low-pressure protector to determine whether it is broken.

  3. 03

    Inspect for refrigerant loss

    Have the refrigerant circuit checked for leaks or undercharge, the common cause of low-pressure trips.

  4. 04

    Repair and recharge

    Repair any leak and recharge to specification so the low-side pressure returns to a normal range.

Keep this fix — get it by email with every ACiQ error code

A clean printable version of this ACiQ PC31 guide + the full ACiQ code pack (20 codes), straight to your inbox. Free.

I am a — required, one click

When to call a professional

PC31 commonly means a refrigerant shortage, and leak detection, repair, and recharging require EPA certification and recovery equipment; pressure-switch testing happens around the outdoor unit's high-voltage electronics. Always contact a licensed HVAC technician for PC31; refrigerant work and protector diagnosis must be carried out by a qualified professional, never attempted without certification.

Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.