Weil McLain F34 Error Code
Low mains voltage. F35 Frequency error. F37 The water pressure in the CH install
Source: ab-80c__wml-aquabalance-series-2-iom.pdf
What does Weil McLain F34 mean?
F34 is a warning indicating the supply voltage has dropped below 100 VAC. This is an indication only — heat demand is not immediately switched off. The fault resolves automatically when voltage returns above 100 VAC. A common cause on AquaBalance boilers is excessive pump loads wired to the boiler's pump connection terminal.
Symptoms
- F34 warning displayed on the control module LCD.
- Boiler may operate at reduced capacity or exhibit unstable ignition.
- Fault clears and recurs if voltage fluctuates around the 100 VAC threshold.
- Other electrical equipment on the same circuit may also show abnormal behavior.
Common causes
- More than one pump wired to the boiler pump connection point, causing voltage drop.
- Utility supply voltage sag during high-demand periods.
- Undersized wiring to the boiler causing significant voltage drop under load.
- Loose electrical connections at the service panel, boiler disconnect, or boiler terminal strip.
Ask the AskWhiz AI about Weil McLain F34
AskWhiz
online
Diagnostic steps
Measure supply voltage at the boiler
With the boiler running, measure AC voltage at the boiler power terminals. A reading below 100 VAC confirms a genuine low-voltage condition. If reading is normal, suspect a sensor or control fault.
Check for multiple pumps on the boiler pump terminal
The AquaBalance is rated for one pump on its pump connection. Verify no more than one circulator is wired to the boiler terminal. Move additional pumps to a separate relay or zone control.
Inspect all electrical connections
Check for loose connections at the boiler disconnect switch, panel breaker, and boiler terminal strip. Tighten all connections and re-measure voltage under load.
Check circuit wiring gauge
Verify the supply circuit uses the wire gauge specified in the boiler manual. Undersized wiring causes voltage drop under motor loads.
Contact utility if voltage is low at the meter
If voltage is below 100 VAC even at the electrical meter, contact the utility provider to report and resolve the low-voltage supply issue.
When to call a professional
Have a licensed electrician evaluate the electrical supply if voltage consistently reads below 100 VAC at the boiler. A technician should also verify the wiring and pump load configuration if F34 appears after any recent electrical or hydronic system changes.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Weil McLain documentation and can diagnose this fault code and guide you through the repair in minutes.
Free tier — 10 messages/month, no credit card.
Other Weil McLain Error Codes
prom parameters Unit Range Def Description Num. Address Description Low High Val
Firmwareversion Num 0 99 04
repeated 3 times in the last 24 hours LP Liquefied Petroleum (Propane) Gas LWCO
repeated 3 times in the last hour A41 Temperature sensor not or bad connected to
generated for 1 hour (con- secutive) See fault F15 A06 No flame after igni- tion
Supply sensor 1 fault Sensor damaged Wiring shorted Check the wiring or replace
Return sensor fault Sensor damaged Wiring shorted Check the wiring or replace th
DHW sensor fault Sensor damaged Wiring shorted Check the wiring or replace the s
flashing (history/fault) ·Push “Reset" once · Push + to scroll error codes, refe
4C - selection). F34 Low mains voltage. F35 Frequency error. F37 The water press
The Exhaust gases temperature sensor error. F14 The CH supply water temperature
The water pressure in the CH installation is near the high level. F27 The exhaus
Sources: freeboilermanuals.com