Ako E18 Error Code
Excessive door openings have been detected and the Check that the door has not b
Source: 3516524A11-10.pdf
What does Ako E18 mean?
E18 indicates that the controller has detected an excessive number of door openings within a defined monitoring period. The controller counts door contact events using the door switch digital input and raises E18 when that count exceeds the configured threshold. This alarm signals that the cold room is experiencing more door activity than operationally expected, which increases heat load and reduces energy efficiency.
Symptoms
- E18 appears on the display.
- Alarm relay activates and audible alarm sounds.
- Cold room temperature may be trending upward due to accumulated heat load from repeated door openings.
- Door opening count has exceeded the configured threshold parameter.
- Alarm may recur frequently in high-traffic operations if the threshold is set too low.
Common causes
- Operational pattern with genuine frequent door openings during a busy period (most common).
- Door not closing fully after each opening, causing multiple contact events from a single entry.
- Door switch sensor fault generating spurious counts.
- Door opening threshold parameter set too low for the actual operational use pattern.
- Door left ajar causing repeated triggering of the door contact.
Ask the AskWhiz AI about Ako E18
AskWhiz
online
Diagnostic steps
Check the cold room door is closing fully
Physically inspect that the door closes and latches completely after each opening. A door that does not close fully generates repeated contact signals and also allows continuous heat ingress.
Inspect the door contact switch
Verify the door contact (magnetic or mechanical switch) is operating correctly. A faulty switch stuck in the open state can generate phantom door-opening counts.
Review the door opening count threshold parameter
Enter the parameter menu and review the door opening count limit. If E18 recurs during normal operations, increase the threshold to reflect the actual usage pattern.
Identify any operational patterns causing excessive openings
Review operational procedures to identify whether excessive door openings can be reduced through process changes, such as batch picking instead of individual trips.
Reset the alarm and monitor door count
Acknowledge and reset E18. Monitor door-opening counts over a representative operating period to determine whether the threshold is correctly set for the installation.
When to call a professional
Call a licensed technician if the door contact switch requires replacement or if the cold room temperature has risen significantly due to accumulated heat load from the excessive door openings. A technician should also assess whether the increased heat load has caused frost buildup on the evaporator requiring a corrective defrost cycle.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Ako documentation and can diagnose this fault code and guide you through the repair in minutes.
Free tier — 10 messages/month, no credit card.
Other Ako Error Codes
/E3 Probe 1/2/3 failure (Open circuit, crossed circuit or temperature outside th
Severe external alarm activated (by digital input) Rdt Defrost alarm concluded d
/ E2/ E3 Probe 1, 2 or, 3 faulty. Severe external alarm activated. AES Indicates
configuration. It allows the creation of up to 5 user profiles, each with a four
Indicates a defrost is underway. After defrosting, the message wilcontinue to be
Access code (Password)request Probe1brokenOpen,rosdcicuit or proeutofrane Memory
Thermal alarm 3 DR RE4 Thermal alarm 4 DR RE5 Thermal alarm 5 DR RE5 Severe exte
E3 Probe 1, 2 or 3 faulty (open circuit, crossover or temperature outside the pr
) (Does not activate alarm relay) (See page 16)
Severe external alarm activated due to digital input 15 or 16 (According to para
Regulation remotely stopped due to digital input 15 or I6; all stages/compressor
E2 Probe 1 or 2 faulty (open circuit, crossover or temperature outside the probe
Sources: help.ako.com, help.ako.com