Quick Answer
Bryant gas furnaces report faults via the Status LED on the control board: count the amber/green flashes, pause, repeat. Common codes include 4 flashes (limit switch open), 3 flashes (pressure switch stuck open), and 6 flashes (flame lost). Bryant is a Carrier brand, so Heil, Tempstar, Comfortmaker, and Payne use the same flash-code chart.
Bryant Troubleshooting Assistant
Get instant AI-powered help for Bryant fault codes and equipment issues via WhatsApp. Our assistant is trained on official manufacturer documentation — available 24/7 for field technicians.
Co-founder & CTO · Reviewed May 2026
What error codes does Bryant display?
Ignition lockout — four failed light attempts; check gas supply, igniter, and flame sensor
Pressure switch stuck closed — inspect tubing, switch, and inducer relay
Pressure switch failed to close — blocked vent, inducer fault, or cracked tubing
High-limit switch open — dirty filter, blower fault, or closed registers
Flame sensed when no call for heat — leaking gas valve or shorted flame sensor wire
Flame proven then lost — weak flame, dirty sensor, or grounding issue
Gas valve circuit fault — open coil, harness break, or board driver failure
Low flame-sense current — clean the flame rod, verify burner ground
Line-voltage polarity reversed — swap L1/N at the disconnect
Gas valve relay shorted — replace the integrated control board