Electrolux Professional FU13 Error Code
Upper inverter communication error
Source: Electrolux Professional 3/UM_05UMC13_ENG01_SKLOVN_1_5_1_1_EPR_UMG_SkyLineOvens_ENG_20250617.pdf
What does Electrolux Professional FU13 mean?
FU13 means the SkyLine oven has a communication error with the upper cavity motor inverter, and the appliance stops. It corresponds to the N°201 upper-inverter communication problem. The control cannot talk to the inverter, typically because of a missing inverter power supply, an unplugged or damaged connector, or a blown fuse.
Symptoms
- FU13 displayed and the appliance stops
- No communication with the upper inverter
- Upper cavity motor not driven
- May follow a power or wiring disturbance
Common causes
- Inverter power supply (AC) missing
- Connector unplugged or damaged
- Fuse F2 blown
Ask the AskWhiz AI about Electrolux Professional FU13
AskWhiz
online
Diagnostic steps
Restart the oven
Restart the oven, as the manual's first action.
Watch for recurrence
If the causes persist, the error will appear again, pointing to a real wiring or power fault.
Note the likely causes
A missing inverter AC supply, an unplugged/damaged connector, or a blown F2 fuse are the documented causes.
Call Service if it persists
If the causes persist, call Service to inspect the inverter wiring and fuse.
When to call a professional
Restart once; if FU13 persists, call an Electrolux Professional engineer. A missing inverter supply, a damaged connector, or a blown F2 fuse are internal electrical faults requiring trained diagnosis and parts. Working inside the inverter and fuse area involves mains-level wiring, so do not attempt it as kitchen staff; a technician must restore communication with the upper motor inverter.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Electrolux Professional documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Electrolux Professional Error Codes
Cavity safety switch triggered (TSC) — cavity over-temperature
Cavity over-temperature (recoverable)
Boiler safety thermostat trips — boiler over-temperature
Boiler over-temperature (recoverable / descale-related)
Boiler thermocouple failure
Boiler water loading timeout
Boiler excessive temperature-rise time (warning)
Boiler level sensor problem
Descale boiler — scale threshold reached (stops cycle)
Descale boiler — scale build-up threshold reached (warning)
Single-point core probe failure
Six-point core probe failure