Quick Answer
Irinox MultiFresh NEXT blast chillers report A-prefixed alarm codes from the control board. Most are automatic-reset probe and door faults — A10 to A12 core probes, A15 chamber probe RV1, A28 open-door — while A53 to A62 are manual-reset condenser temperature alarms that block the cycle until cleared. A04 flags the real-time-clock module.
Irinox Troubleshooting Assistant
Get instant AI-powered help for Irinox fault codes and equipment issues via WhatsApp. Our assistant is trained on official manufacturer documentation — available 24/7 for field technicians.
Co-founder & CEO · Reviewed June 2026
What error codes does Irinox display?
RTC clock-module fault, blocks the cycle; trips after more than 3 days without power
Core probe point 1 (PT1000) interrupted or out of calibration range
Core probe point 2 (PT1000) interrupted or out of calibration range
Core probe point 3 (PT1000) interrupted or out of calibration range
Chamber air probe RV1 fault — blocks the blast-chill cycle
Room temperature probe RV6 fault (automatic reset)
Open-door alarm during a cooling or heating cycle (door switch SQ1)
Ambient room temperature out of range (5 °C low; 38 °C class 4 / 43 °C class 5 high)
Power failure logged during an active cycle
Condenser 1 high condensing temperature — manual reset, blocks the cycle