Irinox A57 Error Code
Condenser 2DT Low Temperature Alarm – Manual Reset (Irinox MultiFresh Next M/ML and L/LL)
Source: Irinox_MULTI_FRESH_NEXT_S_None_ServiceManual_RF_EN_part02.pdf
What does Irinox A57 mean?
The control board has detected an abnormally low temperature at condenser 2, as reported by the DT sensor on that circuit. This manual-reset alarm applies to the larger M/ML and L/LL MultiFresh Next models which are equipped with multiple condenser circuits. The controller has determined that the measured condensing temperature on circuit 2 has fallen below the acceptable minimum, halting the cycle until the fault is investigated and manually cleared.
Symptoms
- A57 alarm code displayed on the control panel, unit in blocked state
- Condenser 2 DT sensor reading is lower than expected for current operating conditions
- Cycle interrupted; unit will not restart without a manual reset
- Possible imbalance between condenser circuits if condenser 1 reads normal while condenser 2 reads low
- Alarm event logged in the controller history with timestamp
Common causes
- Faulty or out-of-calibration DT sensor on condenser 2 generating a false low reading
- Open circuit or damaged wiring in the condenser 2 DT sensor cable
- Refrigerant charge imbalance or loss on the condenser 2 circuit
- Overcooling of condenser 2 due to excessively low ambient or water-supply temperature
- Incorrect calibration offset for condenser 2 DT sensor stored in controller parameters
- Water flow rate too high on water-cooled condenser 2 causing excessive subcooling
Ask the AskWhiz AI about Irinox A57
AskWhiz
online
Diagnostic steps
Read live condenser 2 DT sensor value
Navigate to the live sensor display in the controller service menu and record the condenser 2 DT reading. Compare it against condenser 1 and ambient conditions to determine whether the reading is anomalous.
Inspect sensor wiring for condenser 2
Check the DT sensor wiring harness for condenser 2 from the sensor head to the control board terminal. Look for broken conductors, chafed insulation, or loose terminals that could create an open or high-resistance circuit.
Measure DT sensor resistance
Disconnect the condenser 2 DT sensor and measure its resistance at known ambient temperature. Cross-reference the result with the NTC table in the Irinox service manual; replace the sensor if readings are out of range.
Assess installation and water conditions
For air-cooled units, verify that ambient temperature is within spec. For water-cooled units, check the water inlet temperature and flow rate to condenser 2; excessively cold or high-flow water can legitimately cause low condensing temperature on this circuit.
Verify controller calibration offset
In the controller service parameters, confirm the calibration offset for the condenser 2 DT sensor is set correctly. Correct any erroneous value that is artificially depressing the reported temperature.
Reset and run supervised test cycle
After correcting the identified fault, perform the manual reset. Observe condenser 2 DT readings throughout a full test cycle to confirm they remain within the normal operating band.
When to call a professional
If low condenser 2 temperature persists after sensor, wiring, and calibration checks, escalate to a licensed Irinox-certified refrigeration technician to evaluate refrigerant charge and circuit pressures on condenser 2. Water-cooled installations with suspected control valve or flow regulation issues should also be referred to a qualified technician.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Irinox documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Irinox Error Codes
Upper door open alarm – CP Multi integrated air condensing unit
Clock module RTC alarm – automatic reset, blocks cycle – MULTIFRESH NEXT
Core probe point 1 alarm – automatic reset – MULTIFRESH NEXT
Core probe point 2 alarm – automatic reset – MULTIFRESH NEXT
Core probe point 3 alarm – automatic reset – MULTIFRESH NEXT
Chamber temperature probe (RV1) alarm – automatic reset, blocks cycle – MULTIFRESH NEXT
Defrost end temperature probe (RV5) alarm – automatic reset – MULTIFRESH NEXT
Room temperature probe (RV6) alarm – automatic reset – MULTIFRESH NEXT
Condenser 1 temperature probe alarm (automatic reset / block cycle) – MULTIFRESH NEXT S/M/L and SL/ML/LL
Condenser 2 temperature probe alarm (automatic reset / block cycle) – MULTIFRESH NEXT M/L and ML/LL
Condenser 3 temperature probe alarm (automatic reset / block cycle) – MULTIFRESH NEXT L and LL
Open door alarm during cooling or heating cycle (automatic reset) – MULTIFRESH NEXT