Irinox A60 Error Code
Condenser 2TC Low Temperature Alarm – Manual Reset (Irinox MultiFresh Next M/L and ML/LL)
Source: Irinox_MULTI_FRESH_NEXT_S_None_ServiceManual_RF_EN_part02.pdf
What does Irinox A60 mean?
On MultiFresh Next M/L and ML/LL models, the control board has detected that the TC sensor on condenser 2 is reporting a temperature below the minimum acceptable condensing threshold. This manual-reset, block-cycle alarm indicates that the heat rejection process on condenser 2 circuit is below expected parameters. The fault may stem from a sensor or wiring issue, refrigerant circuit problem, or environmental conditions acting on condenser 2 specifically.
Symptoms
- A60 alarm code active on the control panel, unit in blocked state
- Condenser 2 TC sensor shows an unusually low reading in the controller service display
- Cycle interrupted; unit requires manual reset before it will operate again
- Discrepancy between condenser 2 TC and condenser 1 TC readings under the same conditions
- Repeated alarms after reset if the root cause has not been corrected
Common causes
- Defective TC sensor on condenser 2 producing a false low reading
- Open circuit, broken wire, or loose connector in the condenser 2 TC sensor harness
- Refrigerant undercharge or leak on the condenser 2 circuit
- Installation environment temperature too low relative to operational specifications
- Incorrect calibration offset for condenser 2 TC stored in the controller
- Excessive water flow or very cold water supply overcooling condenser 2 on water-cooled units
Ask the AskWhiz AI about Irinox A60
AskWhiz
online
Diagnostic steps
Compare condenser 2 TC reading to condenser 1 TC
In the controller service menu, read both condenser TC sensors simultaneously. A significantly lower reading on condenser 2 while condenser 1 is normal points to a condenser 2-specific sensor or wiring fault rather than a system-wide problem.
Inspect condenser 2 TC sensor wiring
Trace the TC sensor wiring from the condenser 2 sensor head to the control board. Repair any open circuits, loose connectors, or damaged cable insulation found during the inspection.
Test condenser 2 TC sensor resistance
Disconnect the TC sensor and measure its resistance at known ambient temperature. Reference the NTC table in the Irinox service manual for the expected value and replace the sensor if it falls outside specification.
Evaluate ambient and water supply conditions
Verify that the environment temperature and, for water-cooled models, the water supply temperature and flow rate to condenser 2 are within Irinox's operating specifications. Adjust flow regulation if overcooling is suspected.
Check and correct controller parameter offset
Inspect the calibration offset parameter for condenser 2 TC in the controller service settings. Correct any erroneous offset value that is causing an artificially depressed temperature reading.
Reset alarm and run monitored test
After the fault is resolved, perform the manual reset on the panel. Monitor condenser 2 TC readings throughout a complete test cycle to confirm the value is stable and consistent with condenser 1.
When to call a professional
Escalate to a licensed Irinox-authorized refrigeration technician if condenser 2 TC low readings persist despite sensor and wiring verification, as this may indicate a refrigerant circuit fault on circuit 2 requiring pressure measurement and possible refrigerant handling. Any refrigerant work or advanced controller parameter modification must be carried out by a qualified professional.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Irinox documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Irinox Error Codes
Upper door open alarm – CP Multi integrated air condensing unit
Clock module RTC alarm – automatic reset, blocks cycle – MULTIFRESH NEXT
Core probe point 1 alarm – automatic reset – MULTIFRESH NEXT
Core probe point 2 alarm – automatic reset – MULTIFRESH NEXT
Core probe point 3 alarm – automatic reset – MULTIFRESH NEXT
Chamber temperature probe (RV1) alarm – automatic reset, blocks cycle – MULTIFRESH NEXT
Defrost end temperature probe (RV5) alarm – automatic reset – MULTIFRESH NEXT
Room temperature probe (RV6) alarm – automatic reset – MULTIFRESH NEXT
Condenser 1 temperature probe alarm (automatic reset / block cycle) – MULTIFRESH NEXT S/M/L and SL/ML/LL
Condenser 2 temperature probe alarm (automatic reset / block cycle) – MULTIFRESH NEXT M/L and ML/LL
Condenser 3 temperature probe alarm (automatic reset / block cycle) – MULTIFRESH NEXT L and LL
Open door alarm during cooling or heating cycle (automatic reset) – MULTIFRESH NEXT