05ITW Food Equipment Group

ITW Food Equipment Group 05 Error Code

Wash tank temperature above upper limit

Source: ITW FOOD EQUIPMENT GROUP/00008 EDH-EDL_EUH-EUL Dishwashers Operation and Error Card F48737 (01-23).pdf

What does ITW Food Equipment Group 05 mean?

The wash tank water temperature has risen above its allowed upper limit. The control monitors the main wash tank and trips this error when it reads too hot, which usually indicates a tripped high-limit thermostat or a wash tank heating element that is not switching off properly.

Symptoms

  • Error code 05 shown on the wash tank temperature display
  • Wash water hotter than normal
  • Machine stops or will not complete a cycle
  • Error returns after a restart

Common causes

  • High-limit thermostat tripped on the wash tank
  • Wash tank heating element malfunction (stuck on)
  • Wash tank temperature sensor reading out of range
  • Control fault in the wash tank heat circuit

Ask the AskWhiz AI about ITW Food Equipment Group 05

AskWhiz bot

AskWhiz

online

Hi — I'm the Commercial Kitchen demo. Ask me anything in this domain.

Diagnostic steps

  1. Power the machine off

    Press the power button to switch the dishwasher off and allow roughly 20 minutes for the wash tank to cool down.

  2. Restart as normal

    Press the power button again to restart the machine as you normally would.

  3. Check the wash temperature

    Run a cycle and confirm whether code 05 clears once the wash tank reaches operating temperature.

  4. Call Hobart Service if it persists

    If the error continues to display, the likely cause is a high-limit trip or heating element malfunction; contact Hobart Service at 1-888-4HOBART.

When to call a professional

Contact Hobart Service if code 05 persists after a power-off, cool-down and restart. A wash tank running over temperature usually means a tripped high limit or a heating element that will not shut off, both in the line-voltage heating circuit. An authorized Hobart technician should test the high-limit thermostat, element and sensor before returning the machine to service.