Krupps AL-02 Error Code
Faulty boiler probe — boiler probe not connected, interrupted or shorted; boiler heating disabled
Source: Krupps/Krupps_ADVANCE_ServiceManual_CommercialKitchen.pdf
What does Krupps AL-02 mean?
AL-02 on a Krupps dishwasher indicates a faulty boiler probe: the boiler probe does not seem to be connected — it is interrupted or shorted. As a result, boiler heating is disabled.
Symptoms
- ALARM light flashing on the control panel
- 'AL' on the left digit LEDs with the code on the right
- Cycle start button shows red (alarm state)
- Final rinse water is not hot — boiler heating is disabled
- Poor rinse / sanitising results
Common causes
- Boiler probe not connected to the power board
- Boiler probe wiring interrupted (open circuit)
- Boiler probe shorted
- Loose or damaged probe terminal
Ask the AskWhiz AI about Krupps AL-02
AskWhiz
online
Diagnostic steps
Request a technician
The manual directs the final user to request the intervention of a technician for AL-02; the diagnostic checks are technician-level.
Check the probe connection on the board
Technician check 1: verify the boiler temperature probe is connected correctly on the power board.
Check the probe terminal
Technician check 2: verify the boiler probe terminal is connected correctly (no loose or broken contact).
Replace the probe
Technician check 3: replace the boiler probe if it remains interrupted or shorted after the connection checks.
When to call a professional
If switching the dishwasher off and on does not clear AL-02, call a service technician. The manual's resolution steps — checking the boiler probe's connection on the power board, checking its terminal, and replacing the probe — all involve work inside the machine's wiring and control board and should be done by qualified service personnel, not the operator.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Krupps documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Krupps Error Codes
Faulty boiler probe and tank probe — both temperature probes are faulty; heating is disabled
Faulty tank probe — tank probe not connected, interrupted or shorted
Tank loading timeout — the tank did not fill within the maximum time foreseen
Drain timeout — the tank pressure switch did not open at the end of the total drain cycle
Heating timeout — the dishwasher did not heat the water within the intended maximum time; heating disabled
Exhausted brine — not enough brine (water and salt) for the resin regeneration of the built-in softener
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.