Faulty tank probe — tank probe not connected, interrupted or shorted
Source: Krupps/Krupps_ADVANCE_ServiceManual_CommercialKitchen.pdf
What does Krupps AL-03 mean?
AL-03 on a Krupps dishwasher indicates a faulty tank probe: the tank probe does not seem to be connected — it is interrupted or shorted.
Symptoms
- ALARM light flashing on the control panel
- 'AL' on the left digit LEDs with the code on the right
- Cycle start button shows red (alarm state)
- Tank temperature not read correctly
- Wash performance affected because tank temperature is unknown
Common causes
- Tank probe not connected to the power board
- Tank probe wiring interrupted (open circuit)
- Tank probe shorted
- Loose or damaged probe terminal
Ask the AskWhiz AI about Krupps AL-03
AskWhiz
online
Diagnostic steps
Request a technician
The manual directs the final user to request the intervention of a technician for AL-03; the checks below are technician-level.
Check the probe connection on the board
Technician check 1: verify the tank temperature probe is connected correctly on the power board.
Check the probe terminal
Technician check 2: verify the tank probe terminal is connected correctly.
Replace the probe
Technician check 3: replace the tank probe if it remains interrupted or shorted after the connection checks.
When to call a professional
AL-03 is a probe/wiring fault the manual hands to a technician. If powering the dishwasher off and on does not clear it, call qualified service. Verifying the tank probe's connection at the power board, checking the terminal and replacing the probe all require opening the machine and working on the control board, which is technician work rather than an operator task.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Krupps documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Krupps Error Codes
Faulty boiler probe and tank probe — both temperature probes are faulty; heating is disabled
Faulty boiler probe — boiler probe not connected, interrupted or shorted; boiler heating disabled
Tank loading timeout — the tank did not fill within the maximum time foreseen
Drain timeout — the tank pressure switch did not open at the end of the total drain cycle
Heating timeout — the dishwasher did not heat the water within the intended maximum time; heating disabled
Exhausted brine — not enough brine (water and salt) for the resin regeneration of the built-in softener
AskWhiz Playground
Test your diagnostic skills
Play a real HVAC service call in the AskWhiz Playground — real brands, real fault codes, no signup.
Play a real service call