Sirman E4 Error Code
Hardware error — check communication between keyboard and power supply (PLD 300-330-350 AUT)
Source: Sirman_15354C2GU2S_user-manual_EN.pdf
What does Sirman E4 mean?
The PLD 300-330-350 AUT control has detected a hardware-level communication failure between the operator keyboard/control panel and the power supply board. The two boards are not exchanging data correctly, which prevents safe machine operation. This is an internal electronics fault, not a mechanical or product-related issue. The manual directs the technician to investigate the communication link between these two specific PCB assemblies.
Symptoms
- Display shows 'E4' at startup or during operation
- Machine is unresponsive to keyboard inputs or behaves erratically
- Control panel may display incomplete or garbled information
- Machine does not begin any operational cycle
- Error may be intermittent if caused by a loose connector rather than a failed component
Common causes
- Communication cable or harness between the keyboard PCB and power supply PCB is loose or disconnected
- Damaged or broken communication cable/ribbon between the two boards
- Corroded or damaged connector pins on the keyboard or power supply board
- Failed keyboard PCB preventing it from communicating with the power supply
- Failed power supply PCB or its communication interface
- Electrical noise or interference disrupting the data link between the two boards
Ask the AskWhiz AI about Sirman E4
AskWhiz
online
Diagnostic steps
Power down and access the internal electronics
Disconnect the PLD 300/330/350 AUT from power and open the control housing per the service manual procedure to access the keyboard PCB and power supply PCB and their interconnecting harness.
Inspect the communication cable between boards
Locate the cable or ribbon connecting the keyboard assembly to the power supply board. Check its full length for cuts, pinches, abrasion damage, or connector damage that would interrupt the data link.
Reseat both ends of the communication connector
Disconnect and firmly reseat the communication cable at both the keyboard PCB and the power supply PCB ends. Confirm connector latches or retention mechanisms are fully engaged.
Inspect connector pins for corrosion or damage
Visually examine all pins on both connectors for corrosion, bending, or breakage. Clean corroded pins carefully with appropriate electronics contact cleaner before reconnecting.
Power on and test for E4 clearance
Reassemble, restore power, and observe whether E4 clears at startup and normal keyboard-to-power-supply communication is restored, allowing the machine to function correctly.
When to call a professional
If E4 persists after inspecting and reseating all communication connections, escalate immediately to a licensed Sirman service technician. A failed keyboard PCB or power supply PCB on the PLD 300/330/350 AUT requires board-level diagnosis and component replacement that must be performed by qualified personnel using genuine Sirman parts to ensure safe and correct operation.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Sirman documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Sirman Error Codes
Automatic carriage movement does not work because the carriage is not engaged (VA 4000)
Fuse for automatic carriage movement is activated; automatic carriage movement does not work (VA 4000)
Machine has exceeded 750,000 slices and requires general maintenance (VA 4000)
High mechanical load detected — reduce quantity/weight of product loaded (PLD 300-330-350 AUT)
Slices value set to 0 with slice counter enabled — set the number of slices (PLD 300-330-350 AUT)
Home search failed — check encoder connection, motor connection, and hopper end-of-stroke magnet (PLD 300-330-350 AUT)
Hardware error — check encoder connection (PLD 300-330-350 AUT)
Motor overheating detected on Sirman PLD 300-330-350 AUT – power cycle required; power board may need replacement.
DC bus voltage too low on Sirman PLD 300-330-350 AUT – check incoming mains supply voltage.
DC bus voltage too high on Sirman PLD 300-330-350 AUT – check incoming mains supply voltage.
Requested motor speed too high on Sirman PLD 300-330-350 AUT – reduce product quantity or weight loaded.