Manitowoc Ice E10
Evaporator flooding, circuit 2 (dual-TXV) — early-freeze discharge temperature below the 6-cycle average
Source: Manitowoc Ice/i0500a__man-indigo-r290-sth038-th.pdf
What does Manitowoc Ice E10 mean?
Code E10 is the evaporator-flooding fault for dual-TXV, dual-circuit/single-evaporator machines: during the first 6 minutes of the freeze cycle, the average compressor discharge-line temperature (T2) fell below the average of the six previous cycles.
Symptoms
- E10 logged on a dual-TXV machine
- Discharge line cooler than normal early in freeze
- Ice quality/production drift
Common causes
- Circuit-2 TXV overfeeding
- Overcharge after service
- Control ending harvest with liquid still in the evaporator
Diagnostic steps
- 01
Check the log pattern
Repeated E10s across cycles confirm a real flooding trend on the second circuit.
- 02
Weigh the charge
Verify the exact nameplate charge — overcharge is the simplest explanation and the easiest to rule out.
- 03
Analyze circuit 2
Apply the dual-TXV operational analysis table to isolate the overfeeding valve.
- 04
Repair then verify
After valve or charge correction, confirm discharge-line temperature behavior returns to the normal pattern.
Keep this fix — get it by email with every Manitowoc Ice error code
A clean printable version of this Manitowoc Ice E10 guide + the full Manitowoc Ice code pack (44 codes), straight to your inbox. Free.
When to call a professional
Refrigeration-circuit work on this machine (gauges, refrigerant recovery, TXV or compressor replacement) requires an EPA-certified refrigeration technician, and Indigo units built on R290 propane additionally require flammable-refrigerant service procedures. If the fault returns after the basic checks here, book a qualified ice-machine technician rather than continuing to reset the unit.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Manitowoc Ice error codes
Safety Limit 1 - freeze cycle ran too long (long freeze)
SL#2Safety Limit 2 - harvest cycle ran too long (long harvest)
SL#3Safety Limit 3 - no water sensed during the freeze cycle
E01Long freeze cycle — freeze ran to the 60-minute limit; 6 consecutive trigger the SL#1 shutdown
E02Long harvest cycle — harvest hit the 3.5-minute limit; repeated events log SL#2
E03Input power loss recorded in the event log on power-up (event-log entry only, no alarm)
E04High condenser temperature — liquid line too hot (air- or water-cooled condenser fault)
E05High-pressure control opened — the HPCO safety switch tripped on excess discharge pressure
E07Starving TXV or low on charge — evaporator inlet/outlet (T3/T4) spread over 12°F, 10 consecutive checks
E08TXV fault (dual-circuit/single-evaporator models) — evaporator underfeed signature
E09Evaporator flooding, circuit 1 — early-freeze discharge temperature below the 6-cycle average
E11Refrigeration fault — refrigeration-side abnormality; run full system diagnostics