Quick Answer
Tempstar gas furnaces report faults via an amber Status LED on the SmartLight integrated furnace control: count the slow flashes between long pauses (1F–9F for single-digit codes, plus multi-digit codes like 11, 12, 13). Tempstar is part of International Comfort Products (ICP) under Carrier, so Heil, Comfortmaker, Day & Night, Arcoaire, and KeepRite use the identical flash-code chart.
Tempstar Troubleshooting Assistant
Get instant AI-powered help for Tempstar fault codes and equipment issues via WhatsApp. Our assistant is trained on official manufacturer documentation — available 24/7 for field technicians.
Co-founder & CTO · Reviewed May 2026
What error codes does Tempstar display?
Blower door switch open — close the door fully or check the door interlock micro-switch
External lockout — failed ignition retries; reset by cycling 120 V at the disconnect after fixing the root cause
Pressure switch fault — stuck open at start or stuck closed before inducer runs; check tubing, switch, and inducer
Primary or auxiliary limit open — dirty filter, restricted return, slipping blower, or rollout switch tripped
Flame sensed without a call for heat — leaking gas valve, shorted flame-sensor wire, or hot-surface ignitor grounded
Flame proven then lost — weak flame, dirty flame sensor, marginal burner ground, or low gas pressure mid-cycle
Line-voltage polarity reversed or low 24 V — verify L1/N at the disconnect and confirm chassis ground continuity
Outdoor air thermistor open or shorted — ohm-test against the ICP 10k NTC R-vs-T table, inspect harness for moisture
Defrost board fault — open defrost thermistor (DFT) on the outdoor coil, defrost timeout, or invalid JP1 jumper position
Low-stage gas valve circuit fault — inspect harness, verify 24 V at low-stage terminal, replace valve or IFC if driver failed