Unox WL01 Error Code
Prover humidity probe alarm.
Source: Unox/Unox_XACC-0513-EPLM_ServiceManualAll_CommercialKitchen.pdf
What does Unox WL01 mean?
WL01 is a humidity probe alarm on the prover accessory. The probe that measures humidity in the prover has failed or is disconnected, so humidity control is impaired. As a warning the prover continues with reduced function while flagging the humidity probe problem.
Symptoms
- WL01 warning referencing the prover
- Humidity not controlled correctly in the prover
- Implausible humidity reading
- Warning recurs during operation
Common causes
- Humidity probe disconnected
- Probe out of range or failed
- Wiring fault to the probe
- Connector problem
Ask the AskWhiz AI about Unox WL01
AskWhiz
online
Diagnostic steps
Power down and check the probe
Turn off power and confirm the humidity probe is connected.
Inspect the probe
Check the humidity probe for damage or contamination.
Check the wiring
Inspect the wiring between the humidity probe and the prover board.
Replace the probe
Replace the humidity probe if it does not read correctly and retest.
When to call a professional
WL01 affects the prover accessory. Verifying and replacing the humidity probe requires accessing the prover electronics; have a qualified Unox technician handle it if reconnecting the probe does not clear the warning.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Unox documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Unox Error Codes
Motor thermal protection alarm (permanent error) — the fan motor's thermal protection has tripped.
Safety thermostat alarm — the chamber safety thermostat has tripped above its limit.
Temperature probes alarm — a cooking chamber temperature probe is damaged or disconnected.
Communication error with the power board — the control board lost communication with the power board.
Gas alarm — a fault in the gas burner/ignition system (split into multiple AF23 conditions on later software).
Wrong position of Pollo valve.
Trolley is missing.
Tank missing or safety thermostat fault.
Chamber ceiling temperature too high.
Chamber over-temperature condition (Case 1: T > 150 °C / 302 °F; Case 2: T < 150 °C).
Single-point or multi-point core probe completely damaged.
Chamber temperature probe warning.