Unox WM03
Slowtop core probe warning.
Source: Unox/Unox_XACC-0513-EPLM_ServiceManualAll_CommercialKitchen.pdf
What does Unox WM03 mean?
WM03 is a core probe warning on the Slowtop accessory. The Slowtop core (food) probe is reading abnormally or is disconnected, so core-probe cooking is impaired. As a warning the Slowtop continues with reduced function while flagging the core probe problem.
Symptoms
- WM03 warning referencing the Slowtop
- Core probe cooking unavailable or unreliable
- Implausible core temperature reading
- Warning recurs during operation
Common causes
- Core probe disconnected
- Probe out of range or failed
- Damaged probe cable or connector
- Wiring fault to the board
Diagnostic steps
- 01
Power down and check the probe
Turn off power and confirm the Slowtop core probe is connected.
- 02
Inspect the probe
Check the core probe and cable for visible damage.
- 03
Measure the probe
Measure the probe with a multimeter to confirm it is within range.
- 04
Replace the probe
Replace the core probe if it does not read correctly and retest.
Keep this fix — get it by email with every Unox error code
A clean printable version of this Unox WM03 guide + the full Unox code pack (58 codes), straight to your inbox. Free.
When to call a professional
WM03 affects the Slowtop accessory. Verifying and replacing the core probe requires the correct Unox part and accessory access; have a qualified Unox technician handle it if reconnecting the probe does not clear the warning.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Unox error codes
Motor thermal protection alarm (permanent error) — the fan motor's thermal protection has tripped.
AF02Safety thermostat alarm — the chamber safety thermostat has tripped above its limit.
AF03Temperature probes alarm — a cooking chamber temperature probe is damaged or disconnected.
AF04Communication error with the power board — the control board lost communication with the power board.
AF23Gas alarm — a fault in the gas burner/ignition system (split into multiple AF23 conditions on later software).
AF24Wrong position of Pollo valve.
AF25Trolley is missing.
AF26Tank missing or safety thermostat fault.
AF39Chamber ceiling temperature too high.
AF41Chamber over-temperature condition (Case 1: T > 150 °C / 302 °F; Case 2: T < 150 °C).
AF43Single-point or multi-point core probe completely damaged.
WF01Chamber temperature probe warning.