Quick Answer
Frymaster (Welbilt / Ali Group, sister to Pitco) builds US commercial fryers — FilterQuick, FootPrint Pro, MJ-Series, OCF / BIGLA30-T, and McDonald's-spec QSR lines. M3000 / M4000 controllers display E13 (RTD probe), E16 / E17 / E18 (software / hardware / catastrophic high-limit), and HELP (gas ignition lockout); legacy displays show PROB, HOT, and CALL TECH.
Frymaster Troubleshooting Assistant
Get instant AI-powered help for Frymaster fault codes and equipment issues via WhatsApp. Our assistant is trained on official manufacturer documentation — available 24/7 for field technicians.
Co-founder & CEO · Reviewed May 2026
What error codes does Frymaster display?
RTD probe reads outside valid range on M3000 / M4000 / FQ4000; ohm probe (~113 Ω at room, ~100 Ω at 0 °C); zero or OL = replace probe with OEM part and Loctite PST56765 sealant.
Software high-limit at 410 °F (210 °C) — stuck latch / heat relay on SIB board, contaminated OIB sensor, or probe under-reading; discard oil after the event.
Mechanical bi-metallic high-limit switch opened independently of controller; manually reset after cooling, replace if no continuity at ambient, then diagnose root overheat.
Catastrophic overheat — vat above 460 °F (238 °C) with high-limit switch failed closed; disconnect power immediately, do not drain, call 1-800-551-8633.
Legacy 1814 / RE / Pro Series equivalent of E13; same RTD diagnostic flow, ohm probe, replace if open / shorted; persistent PROB with good probe = controller board fault.
Legacy 1814 / RE display equivalent of E16 — oil above 410 °F; clean OIB sensor, verify probe accuracy, inspect SIB latch / heat relays (LEDs 1 and 3); discard oil.
Gas-fryer ignition lockout — drain valve / drain microswitch, gas supply pressure, flame-sensing rod oxidation, high-limit at ambient, gas-valve coil resistance (Honeywell 400–650 Ω, Robertshaw 71–75 Ω).
Generic service-required prompt on M3000 / M4000 / FQ4000; read service-mode error log (M3000 enter code 1656) for the underlying SIB / OIB / VIB / CAN-bus fault.
Filtration / drain-safety related fault on FilterQuick and OCF models — drain handle not fully closed, drain microswitch failed in the open position, or pan-not-installed switch open; verify mechanical position before electrical diagnosis.
Heat-circuit / contactor fault on M3000-class electric BIGLA30-T — SIB board not seeing element current draw despite heat command; check element continuity, contactor coil and main contacts, and 240 V supply phasing.