Manitowoc Ice SERVICE LIMIT 4
USE0050: condensate pump fault — 4 flashes of the service LED
Source: Manitowoc Ice/use0050a__man-use0050-sth111-th.pdf
What does Manitowoc Ice SERVICE LIMIT 4 mean?
On the USE0050, Service Limit 4 is the condensate-pump fault, shown as 4 flashes of the service LED. The machine shuts down if the float switch in the condensate pump is open, or if the jumper in the ice machine's wire harness is not in place.
Symptoms
- Machine off with 4 flashes on the service LED
- Condensate pump reservoir full or overflowing
- Fault immediately after installation or service (jumper missing)
Common causes
- Failed condensate pump
- Restricted drain line from the condensate pump
- Harness jumper not in place
Diagnostic steps
- 01
Check the pump
Verify the condensate pump runs and empties its reservoir; a full reservoir opens the safety float.
- 02
Clear the drain
Check the drain line from the pump for restriction and clear it.
- 03
Verify the jumper
On installs without a condensate pump, confirm the harness jumper is in place.
- 04
Retest
Clear the fault and confirm the machine completes cycles without the 4-flash code.
Keep this fix — get it by email with every Manitowoc Ice error code
A clean printable version of this Manitowoc Ice SERVICE LIMIT 4 guide + the full Manitowoc Ice code pack (44 codes), straight to your inbox. Free.
When to call a professional
Refrigeration-system diagnosis and electrical work on this machine belong with a qualified commercial ice-machine technician (EPA certification for refrigerant work). If the service limit returns after the checks here, stop resetting the machine and book service — repeated safety-limit trips indicate an unresolved underlying fault.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Manitowoc Ice error codes
Safety Limit 1 - freeze cycle ran too long (long freeze)
SL#2Safety Limit 2 - harvest cycle ran too long (long harvest)
SL#3Safety Limit 3 - no water sensed during the freeze cycle
E01Long freeze cycle — freeze ran to the 60-minute limit; 6 consecutive trigger the SL#1 shutdown
E02Long harvest cycle — harvest hit the 3.5-minute limit; repeated events log SL#2
E03Input power loss recorded in the event log on power-up (event-log entry only, no alarm)
E04High condenser temperature — liquid line too hot (air- or water-cooled condenser fault)
E05High-pressure control opened — the HPCO safety switch tripped on excess discharge pressure
E07Starving TXV or low on charge — evaporator inlet/outlet (T3/T4) spread over 12°F, 10 consecutive checks
E08TXV fault (dual-circuit/single-evaporator models) — evaporator underfeed signature
E09Evaporator flooding, circuit 1 — early-freeze discharge temperature below the 6-cycle average
E10Evaporator flooding, circuit 2 (dual-TXV) — early-freeze discharge temperature below the 6-cycle average