Manitowoc Ice SERVICE LIMIT 5
USE0050: full bin fault — 5 flashes of the service LED
Source: Manitowoc Ice/use0050a__man-use0050-sth111-th.pdf
What does Manitowoc Ice SERVICE LIMIT 5 mean?
On the USE0050, Service Limit 5 is the full-bin fault, shown as 5 flashes of the service LED. It is raised when power is on and the ice machine has remained off for 48 hours with a full-bin condition.
Symptoms
- Machine idle for days with a full bin and 5 flashes on the service LED
- Machine doesn't restart after ice is removed
Common causes
- Bin genuinely full for 48+ hours
- Bin-sensing problem holding the machine in full-bin state
Diagnostic steps
- 01
Empty the bin
Remove ice and confirm the machine restarts on its own.
- 02
Check the bin sensing
If it won't restart with an empty bin, test the bin switch/sensing per the component check procedures.
- 03
Confirm normal cycling
Run a full cycle and verify the code clears.
Keep this fix — get it by email with every Manitowoc Ice error code
A clean printable version of this Manitowoc Ice SERVICE LIMIT 5 guide + the full Manitowoc Ice code pack (44 codes), straight to your inbox. Free.
When to call a professional
Refrigeration-system diagnosis and electrical work on this machine belong with a qualified commercial ice-machine technician (EPA certification for refrigerant work). If the service limit returns after the checks here, stop resetting the machine and book service — repeated safety-limit trips indicate an unresolved underlying fault.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Manitowoc Ice error codes
Safety Limit 1 - freeze cycle ran too long (long freeze)
SL#2Safety Limit 2 - harvest cycle ran too long (long harvest)
SL#3Safety Limit 3 - no water sensed during the freeze cycle
E01Long freeze cycle — freeze ran to the 60-minute limit; 6 consecutive trigger the SL#1 shutdown
E02Long harvest cycle — harvest hit the 3.5-minute limit; repeated events log SL#2
E03Input power loss recorded in the event log on power-up (event-log entry only, no alarm)
E04High condenser temperature — liquid line too hot (air- or water-cooled condenser fault)
E05High-pressure control opened — the HPCO safety switch tripped on excess discharge pressure
E07Starving TXV or low on charge — evaporator inlet/outlet (T3/T4) spread over 12°F, 10 consecutive checks
E08TXV fault (dual-circuit/single-evaporator models) — evaporator underfeed signature
E09Evaporator flooding, circuit 1 — early-freeze discharge temperature below the 6-cycle average
E10Evaporator flooding, circuit 2 (dual-TXV) — early-freeze discharge temperature below the 6-cycle average