Coreco AH2 Error Code
Carel RTN400 controller — HIGH temperature alarm 2
Source: Coreco_rtn400_instruction_sheet_9is24288-1_rel0413_en_termostatos.pdf
What does Coreco AH2 mean?
On the Coreco controller (Carel RTN400), AH2 is hIGH temperature alarm 2: value read by probe 2 exceeds HA2 after time set in tA2; label AH2 recorded in folder ALr; no effect on control.
Symptoms
- Display/record shows AH2 in the ALr alarm folder
- Cabinet warmer than intended
- No direct effect on control (alarm is signalled)
Common causes
- Door openings / hot load
- Dirty condenser or restricted airflow
- Refrigeration fault (low charge, failing compressor/fan)
- Alarm threshold/delay set too tight
Ask the AskWhiz AI about Coreco AH2
AskWhiz
online
Diagnostic steps
Confirm the high-temperature condition
AH2 means the probe exceeded its HA threshold after the alarm delay. Note the temperature.
Review thresholds and cooling
Check HA/tA thresholds, doors, loading and a clean condenser.
When to call a professional
If the alarm reflects a genuine refrigeration fault, have a qualified refrigeration technician diagnose the sealed system; this work is reserved for qualified personnel.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Coreco documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Coreco Error Codes
Control probe (probe 1) error — signal interrupted, short-circuited or incompatible probe
Evaporator / defrost probe (probe 2) error — signal interrupted, short-circuited or incompatible probe
Condenser / product probe (probe 3) error — signal interrupted, short-circuited or incompatible probe
Immediate or delayed alarm from the multifunction digital input (external alarm)
Open-door alarm from the door-switch digital input
Low-temperature alarm — measured temperature below set point by more than parameter AL
High-temperature alarm — measured temperature above set point by more than parameter AH
Unit parameter reading (data) error — saved configuration data error
Operating parameter reading (data) error — manual reset
Defrost ended by timeout — last defrost stopped on maximum duration, not on temperature
Defrost running — status message shown during a defrost cycle (not an alarm)
Dirty-condenser warning/alarm — pre-alarm (cht) between Ac-AE and Ac, then alarm (CHt) when Ac is exceeded and refrigeration stops (manual reset)