Coreco CA
Dixell XW controller — serious external / pressure-switch alarm
Source: Coreco_1592027610-xw60lt-xw60lrt-gb-r10-13022012_termostatos.pdf
What does Coreco CA mean?
On the Coreco controller (Dixell XW30/XW60/XW70), CA is a serious external alarm when a digital input is set as bAL, or a pressure-switch alarm when set as PAL. All regulation outputs are switched OFF while CA is active.
Symptoms
- Display shows CA
- All outputs OFF (refrigeration stopped)
- Buzzer/alarm relay active
- On PAL: nPS pressure-switch trips within the did window
Common causes
- Serious external alarm on a bAL-configured input
- Pressure switch tripped (PAL) — high/low pressure
- Repeated pressure-switch activations reaching nPS within did
- Fault in the connected protection device
- Digital-input wiring or i1F/i2F configuration issue
Diagnostic steps
- 01
Recognise the shutdown
CA stops all outputs. Determine whether the input is bAL (serious external) or PAL (pressure switch).
- 02
Investigate the protection device
For PAL, inspect the pressure switch and the refrigeration condition that tripped it; for bAL, inspect the external protection device.
- 03
Reset per the manual
For repeated PAL trips reaching nPS, switch the instrument off and on to restart regulation after the cause is fixed.
Keep this fix — get it by email with every Coreco error code
A clean printable version of this Coreco CA guide + the full Coreco code pack (49 codes), straight to your inbox. Free.
When to call a professional
CA indicates a serious/pressure fault that stops the unit. Have a qualified refrigeration technician diagnose the pressure or protection condition before returning it to service; this work is reserved for qualified personnel.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Coreco error codes
Control probe (probe 1) error — signal interrupted, short-circuited or incompatible probe
E1Evaporator / defrost probe (probe 2) error — signal interrupted, short-circuited or incompatible probe
E2Condenser / product probe (probe 3) error — signal interrupted, short-circuited or incompatible probe
IAImmediate or delayed alarm from the multifunction digital input (external alarm)
dOrOpen-door alarm from the door-switch digital input
LOLow-temperature alarm — measured temperature below set point by more than parameter AL
HIHigh-temperature alarm — measured temperature above set point by more than parameter AH
EEUnit parameter reading (data) error — saved configuration data error
EFOperating parameter reading (data) error — manual reset
EdDefrost ended by timeout — last defrost stopped on maximum duration, not on temperature
dFDefrost running — status message shown during a defrost cycle (not an alarm)
CHtDirty-condenser warning/alarm — pre-alarm (cht) between Ac-AE and Ac, then alarm (CHt) when Ac is exceeded and refrigeration stops (manual reset)