Dixell XW controller — high-temperature alarm

Source: Coreco_1592027610-xw60lt-xw60lrt-gb-r10-13022012_termostatos.pdf

Want this fix in your inbox? Full HA guide + every Coreco code, printable, free.

What does Coreco HA mean?

On the Coreco controller (Dixell XW30/XW60/XW70), HA is the high-temperature alarm: the cabinet temperature measured by the alarm probe has gone above the alarm limit (AND above the ALU maximum-temperature threshold), after the ALd alarm delay. Outputs are unchanged; regulation continues while the alarm is signalled.

Symptoms

  • Display shows HA (alternating with temperature)
  • Buzzer sounds and the alarm relay activates
  • Cabinet running warmer than the intended set point
  • Risk to product if the high temperature is sustained

Common causes

  • Frequent or prolonged door openings
  • Dirty condenser or restricted airflow reducing cooling
  • Recent defrost or heavy/hot product load (within the alarm-bypass time dAo)
  • Refrigeration fault (low charge, failing compressor/fan)
  • Alarm threshold ALU / delay ALd set too tight

Diagnostic steps

  1. 01

    Confirm the high-temperature condition

    HA means the alarm probe read a temperature above the ALU limit for longer than the ALd delay. Note the displayed temperature to confirm.

  2. 02

    Review the alarm parameters

    Check ALU (max) / ALL (min), ALd (alarm delay) and ALC (absolute vs relative to set point), and remember the alarm is bypassed for dAo after power-up and after defrost.

  3. 03

    Reduce heat loads and check cooling

    Avoid prolonged door openings and hot product; confirm the condenser is clean and airflow unobstructed, since a dirty condenser keeps the cabinet above set point.

Keep this fix — get it by email with every Coreco error code

A clean printable version of this Coreco HA guide + the full Coreco code pack (49 codes), straight to your inbox. Free.

I am a — required, one click

When to call a professional

If HA persists once doors, loading, thresholds and (for high temp) a clean condenser are ruled out, a refrigeration fault may be responsible. Have a qualified refrigeration technician diagnose the sealed system; this work is reserved for qualified personnel.