What does Coreco LA mean?

On the Coreco controller (Dixell XW30/XW60/XW70), LA is the low-temperature alarm: the cabinet temperature measured by the alarm probe has gone below the alarm limit (AND below the ALL minimum-temperature threshold), after the ALd alarm delay. Outputs are unchanged; regulation continues while the alarm is signalled.

Symptoms

  • Display shows LA (alternating with temperature)
  • Buzzer sounds and the alarm relay activates
  • Cabinet running colder than the intended set point
  • Product over-chilling / freezing risk in a non-freezer cabinet

Common causes

  • Temperature fell below the low-temperature limit
  • Refrigeration over-cooling (control or compressor staying on)
  • Alarm threshold ALL / delay ALd set too tight
  • Control probe reading lower than actual

Diagnostic steps

  1. 01

    Confirm the low-temperature condition

    LA means the alarm probe read a temperature below the ALL limit for longer than the ALd delay. Note the displayed temperature to confirm.

  2. 02

    Review the alarm parameters

    Check ALU (max) / ALL (min), ALd (alarm delay) and ALC (absolute vs relative to set point), and remember the alarm is bypassed for dAo after power-up and after defrost.

  3. 03

    Investigate over-cooling

    Verify the control probe reading against a thermometer and confirm the compressor is not running past the set point.

Keep this fix — get it by email with every Coreco error code

A clean printable version of this Coreco LA guide + the full Coreco code pack (49 codes), straight to your inbox. Free.

I am a — required, one click

When to call a professional

If LA persists once doors, loading, thresholds and (for high temp) a clean condenser are ruled out, a refrigeration fault may be responsible. Have a qualified refrigeration technician diagnose the sealed system; this work is reserved for qualified personnel.

Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.

Open a ticket — free account

Other Coreco error codes