Coreco LA Error Code
Dixell XW controller — low-temperature alarm
Source: Coreco_1592027610-xw60lt-xw60lrt-gb-r10-13022012_termostatos.pdf
What does Coreco LA mean?
On the Coreco controller (Dixell XW30/XW60/XW70), LA is the low-temperature alarm: the cabinet temperature measured by the alarm probe has gone below the alarm limit (AND below the ALL minimum-temperature threshold), after the ALd alarm delay. Outputs are unchanged; regulation continues while the alarm is signalled.
Symptoms
- Display shows LA (alternating with temperature)
- Buzzer sounds and the alarm relay activates
- Cabinet running colder than the intended set point
- Product over-chilling / freezing risk in a non-freezer cabinet
Common causes
- Temperature fell below the low-temperature limit
- Refrigeration over-cooling (control or compressor staying on)
- Alarm threshold ALL / delay ALd set too tight
- Control probe reading lower than actual
Ask the AskWhiz AI about Coreco LA
AskWhiz
online
Diagnostic steps
Confirm the low-temperature condition
LA means the alarm probe read a temperature below the ALL limit for longer than the ALd delay. Note the displayed temperature to confirm.
Review the alarm parameters
Check ALU (max) / ALL (min), ALd (alarm delay) and ALC (absolute vs relative to set point), and remember the alarm is bypassed for dAo after power-up and after defrost.
Investigate over-cooling
Verify the control probe reading against a thermometer and confirm the compressor is not running past the set point.
When to call a professional
If LA persists once doors, loading, thresholds and (for high temp) a clean condenser are ruled out, a refrigeration fault may be responsible. Have a qualified refrigeration technician diagnose the sealed system; this work is reserved for qualified personnel.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Coreco documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Coreco Error Codes
Control probe (probe 1) error — signal interrupted, short-circuited or incompatible probe
Evaporator / defrost probe (probe 2) error — signal interrupted, short-circuited or incompatible probe
Condenser / product probe (probe 3) error — signal interrupted, short-circuited or incompatible probe
Immediate or delayed alarm from the multifunction digital input (external alarm)
Open-door alarm from the door-switch digital input
Low-temperature alarm — measured temperature below set point by more than parameter AL
High-temperature alarm — measured temperature above set point by more than parameter AH
Unit parameter reading (data) error — saved configuration data error
Operating parameter reading (data) error — manual reset
Defrost ended by timeout — last defrost stopped on maximum duration, not on temperature
Defrost running — status message shown during a defrost cycle (not an alarm)
Dirty-condenser warning/alarm — pre-alarm (cht) between Ac-AE and Ac, then alarm (CHt) when Ac is exceeded and refrigeration stops (manual reset)