Coreco LA2 Error Code
Dixell XW controller — condenser low-temperature alarm
Source: Coreco_1592027610-xw60lt-xw60lrt-gb-r10-13022012_termostatos.pdf
What does Coreco LA2 mean?
On the Coreco controller (Dixell XW30/XW60/XW70), LA2 is the condenser low-temperature alarm: the condenser probe has fallen below the AL2 limit after the Ad2 delay. What happens to the compressor depends on the bLL parameter.
Symptoms
- Display shows LA2
- Condenser temperature below the AL2 limit
- Compressor behaviour depends on bLL
Common causes
- Condenser probe reading low
- Very low ambient temperature
- AL2 threshold set too tight
- Condenser probe fault
Ask the AskWhiz AI about Coreco LA2
AskWhiz
online
Diagnostic steps
Check the condenser probe reading
Compare the condenser probe against the actual temperature; LA2 means it fell below AL2.
Review AL2/bLL/Ad2
Confirm the condenser low-temperature parameters suit the installation and ambient.
When to call a professional
If LA2 reflects a genuine fault rather than a parameter/ambient issue, have a qualified refrigeration technician investigate; electrical access is reserved for qualified personnel.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Coreco documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Coreco Error Codes
Control probe (probe 1) error — signal interrupted, short-circuited or incompatible probe
Evaporator / defrost probe (probe 2) error — signal interrupted, short-circuited or incompatible probe
Condenser / product probe (probe 3) error — signal interrupted, short-circuited or incompatible probe
Immediate or delayed alarm from the multifunction digital input (external alarm)
Open-door alarm from the door-switch digital input
Low-temperature alarm — measured temperature below set point by more than parameter AL
High-temperature alarm — measured temperature above set point by more than parameter AH
Unit parameter reading (data) error — saved configuration data error
Operating parameter reading (data) error — manual reset
Defrost ended by timeout — last defrost stopped on maximum duration, not on temperature
Defrost running — status message shown during a defrost cycle (not an alarm)
Dirty-condenser warning/alarm — pre-alarm (cht) between Ac-AE and Ac, then alarm (CHt) when Ac is exceeded and refrigeration stops (manual reset)