Coreco noP Error Code
Dixell XW controller — no parameter / probe not enabled (display message)
Source: Coreco_1592027610-xw60lt-xw60lrt-gb-r10-13022012_termostatos.pdf
What does Coreco noP mean?
On the Coreco controller (Dixell XW30/XW60/XW70), noP is a display message: in programming it means no parameter is present in the Pr1 user menu, and on the display (or in dP2/dP3/dP4) it means the selected probe is not enabled.
Symptoms
- Display shows noP in the Pr1 menu (no user parameters)
- noP when trying to view a probe that is not enabled
Common causes
- No parameters moved to the Pr1 user level
- The selected probe (P2/P3/P4) is not enabled/fitted
Ask the AskWhiz AI about Coreco noP
AskWhiz
online
Diagnostic steps
Understand the message
noP is informational, not a fault: either Pr1 has no parameters, or the probe you tried to display is not enabled.
Enable the probe or use the hidden menu
To read a probe, enable it in the configuration; to see all parameters, use the Pr2 hidden menu.
When to call a professional
noP is normally an informational/configuration message and does not by itself require service. Involve a technician only if a probe that should be enabled will not report.
Stop searching through PDFs. Our AI assistant on WhatsApp is trained on official Coreco documentation and can diagnose this fault code and guide you through the repair in minutes.
5 free questions per bot in your browser — no signup.
Other Coreco Error Codes
Control probe (probe 1) error — signal interrupted, short-circuited or incompatible probe
Evaporator / defrost probe (probe 2) error — signal interrupted, short-circuited or incompatible probe
Condenser / product probe (probe 3) error — signal interrupted, short-circuited or incompatible probe
Immediate or delayed alarm from the multifunction digital input (external alarm)
Open-door alarm from the door-switch digital input
Low-temperature alarm — measured temperature below set point by more than parameter AL
High-temperature alarm — measured temperature above set point by more than parameter AH
Unit parameter reading (data) error — saved configuration data error
Operating parameter reading (data) error — manual reset
Defrost ended by timeout — last defrost stopped on maximum duration, not on temperature
Defrost running — status message shown during a defrost cycle (not an alarm)
Dirty-condenser warning/alarm — pre-alarm (cht) between Ac-AE and Ac, then alarm (CHt) when Ac is exceeded and refrigeration stops (manual reset)