Thermal cut-out in wash pump 2 tripped — machine can continue at reduced operation
Source: 89000013_manual_9110_15_en.pdf
What does Jeros AL 04 mean?
AL 04 means the thermal cut-out protecting wash pump 2 has tripped because the pump was overloaded. The manual notes the machine can continue at reduced operation. If the alarm reoccurs, the manual calls for an engineer.
Symptoms
- AL 04 shown on the operating panel display
- Machine keeps running at reduced operation (wash pump 2 out)
- Alarm returns on subsequent cycles
Common causes
- Wash pump 2 overloaded, tripping its thermal cut-out
- Overload condition that persists across cycles
Diagnostic steps
- 01
Note that reduced operation is permitted
Per the manual the machine can continue at reduced operation with AL 04 active — you are not forced to stop mid-service.
- 02
Switch the machine OFF and then ON again when practical
Power-cycle to reset the control and see whether the trip was transient.
- 03
If AL 04 reoccurs, call an engineer
A repeating wash-pump-2 overload needs service-level diagnosis per the manual.
Keep this fix — get it by email with every Jeros error code
A clean printable version of this Jeros AL 04 guide + the full Jeros code pack (12 codes), straight to your inbox. Free.
When to call a professional
The manual allows reduced operation, so AL 04 is not an emergency stop — but if the error reoccurs, call an engineer. Running long-term on one wash pump degrades wash results and leaves the underlying overload unaddressed.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Jeros error codes
Temperature sensor in wash tank disconnected or short-circuited
AL 02Temperature sensor in rinse tank disconnected or short-circuited
AL 03Thermal cut-out in wash pump 1 tripped — wash pump overloaded
AL 05Thermal cut-out in rinse pump triggered — machine can continue at reduced operation
AL 06Wash frame motor malfunction — disconnected, short-circuited or travel time exceeded
AL 07Lid contact malfunction — not switching
AL 08Lid hoist's maximum travel time exceeded
AL 09Overheating of wash water — temperature above 85°C
AL 10Overheating of rinse water — temperature above 97°C
AL 11Filling time for rinse tank exceeded
AL 13Incorrect phase sequence — reverse L1 and L2 at the main switch