Jeros AL 05
Thermal cut-out in rinse pump triggered — machine can continue at reduced operation
Source: 89000013_manual_9110_15_en.pdf
What does Jeros AL 05 mean?
AL 05 means the thermal cut-out protecting the rinse pump has triggered because the rinse pump was overloaded. The manual notes the machine can continue at reduced operation, and instructs an engineer call-out if the error reoccurs.
Symptoms
- AL 05 shown on the operating panel display
- Machine continues at reduced operation while the alarm is active
- Alarm returns on subsequent cycles
Common causes
- Rinse pump overloaded, triggering its thermal cut-out
- Overload condition that persists across cycles
Diagnostic steps
- 01
Note that reduced operation is permitted
Per the manual the machine can continue at reduced operation with AL 05 active.
- 02
Switch the machine OFF and then ON again when practical
Power-cycle the machine to reset the control after the thermal event.
- 03
If AL 05 reoccurs, call an engineer
A repeating rinse-pump overload needs an engineer per the manual — rinse performance is hygiene-relevant on these machines.
Keep this fix — get it by email with every Jeros error code
A clean printable version of this Jeros AL 05 guide + the full Jeros code pack (12 codes), straight to your inbox. Free.
When to call a professional
Call an engineer if AL 05 reoccurs after a power cycle, as the manual instructs. The rinse stage is what brings final-rinse water to temperature at the nozzles, so a repeatedly tripping rinse pump should not be worked around indefinitely.
Don't want to DIY this? Open a service ticket on AskWhiz and get it handled — pay per ticket, no subscription.
Open a ticket — free accountOther Jeros error codes
Temperature sensor in wash tank disconnected or short-circuited
AL 02Temperature sensor in rinse tank disconnected or short-circuited
AL 03Thermal cut-out in wash pump 1 tripped — wash pump overloaded
AL 04Thermal cut-out in wash pump 2 tripped — machine can continue at reduced operation
AL 06Wash frame motor malfunction — disconnected, short-circuited or travel time exceeded
AL 07Lid contact malfunction — not switching
AL 08Lid hoist's maximum travel time exceeded
AL 09Overheating of wash water — temperature above 85°C
AL 10Overheating of rinse water — temperature above 97°C
AL 11Filling time for rinse tank exceeded
AL 13Incorrect phase sequence — reverse L1 and L2 at the main switch